在曩昔newsletter中,咱们介绍了不同规范安排OTA测验规范的异同. 在本次的newsletter中, MORLAB的工程师为我们降解一下后3GP/ETSI的测验后续内容,TRS的测验
3GPP/ETSI测验规范
FDD的TRS测验
测验用的人头模型与典型的SAR测验人头模型相同,安排液成分要求也相同。其摆放如下图所示
丈量天线与被测物间有必要满意:
TRS的推导公式:
实践计算公式:
TRS测验分为最低要求及均匀要求,意即限值分两种给出,一个是最差的限值,一个是均匀限值,测验成果假如超出恣意一个限值则判定为不合格:
均匀值计算方法:
最低限值计算方法:
测验过程:
•EUT处于最大功率发射
•靠近人头模型
•在EUT支撑的每一个频段,对高中低三个信道进行测验
•经过操控EUT的方位,三维空间
•丈量各点的有用辐射功率EIs,
•30度步长进行测验
限值如下表所示:
Operating Band |
Unit |
||
Average |
Max |
||
I |
dBm/3.84 MHz |
-99.7 |
-96.2 |
II |
dBm/3.84 MHz |
-97.7 |
-94.2 |
III |
dBm/3.84 MHz |
-96.7 |
-93.2 |
IV |
dBm/3.84 MHz |
-99.7 |
-96.2 |
V |
dBm/3.84 MHz |
TBD |
TBD |
VI |
dBm/3.84 MHz |
TBD |
TBD |
VII |
dBm/3.84 MHz |
-97.7 |
-94.2 |
VIII |
dBm/3.84 MHz |
TBD |
TBD |
IX |
dBm/3.84 MHz |
-98.7 |
-95.2 |
NOTE 1 For Power Class 3, 3bis and 4 this shall be achieved at the maximum output power. NOTE 2 For the UE which supports both Band III and Band IX operating frequencies, the reference level of TDB dBm TRS [average and min] shall apply for Band IX. NOTE3 Applicable for dual-mode GSM/UMTS. |
GSM的测验要求与FDD根本共同,除了测验频点及频段不同。其限值暂不决。
关于3GPP和CTIA的OTA测验介绍现已结束,下期将会介绍一下产品的实践测验。